Sony KL-W9000 Projection Television User Manual


 
– 34 –
KL-W7000/W9000
RM-Y980
Adjustment Items and Procedure Tools and Test Points Adjustment Places Illustration Waveforms and Values
Signals
* A : 8.30±0.02Vp-p
* B : 3.45±0.10Vp-p
* 10 IRE ~20IRE : F800 : 20mV
* Oscilloscope
* DC power
* TP5603 [B-SIG2]
* TP5411 [GLBS]
5. Adjust *RV so that the forward 10 IRE ~ reverse 10 IRE (A) be-
comes *8.30±0.02Vp-p.
Adjustment is no good when 0 IRE ~ 10 IRE voltage is below
100mV.
6. Confirm that forward 100 IRE ~ reverse 100 IRE (B) is
*3.45±0.10Vp-p.
* RV5402 [GL. BIAS]
* RV5603 [GL. GAIN]
B channel
1. Connect *oscilloscope to *TP5603.
2. *DC power, apply 3.60±0.02V to *TP5611.
3. Adjust *RV so that 10 IRE ~ 20 IRE becomes *800±20mV.
Confirm that 0 IRE ~ 10 IRE voltage is over 7.1V.
10 IRE
10 IRE
100 IRE
10 IRE
B
A
20 IRE
10 IRE