118
5.3 Factory Default Value
5.3.1 Main Menu
Menu
Main
menu
Sub menu1 Sub menu2 Sub menu3
Default Value Remarks
Channel Channel No CH-1~CH-4
Camera Name CH-1~CH-4
Camera Hide Off
Model No NONE URX-500,
PELCO-D,
SENSORMATIC,
VICON,
SUNGJIN
MRX-1000
SRX-100B
PTZ ID Channel No
Reverse Control Pan NO
Tilt NO
Zoom NO
Focus NO
PTZ Setup
RS-485 Setting Baud Rate 9600
Default
Contrast 9 Level Max. 16 Levels
Brightness 9 Level “
Hue 9 Level “
Sharpness 9 Level “
Picture Setting
Default
Camera
Setup
Sequence Time 2 sec
Record Type MUX MUX/QUAD
MUX 360*240(NTSC)
360*288(PAL)
Resolution
QUAD 720*480(NTSC)
720*576(PAL)
Audio Sync NONE
Channel No CH1
Quality FINE 4 Levels
Frame Rate (FPS) 30
Record
Setup
Channel
Record Mode MANUAL
Channel No CH-1
Sensitivity 5 Level 8 Levels
Motion Detection
Setting
Detection Zone ALL
Sensor Type N.O. / N.C. N.O. Sensor Setting
Channel Link CH1~CH4 NONE
Sensor1~Sensor4 OFF
Motion1~Motion4 OFF
Alarm Output
Relay Time 0 sec
Post-Alarm Record 10 sec 10, 20, 20, 40, 50, 60
sec
FTP Server IP Blank
Event
Setup
FTP Setting
ID Anonymous