14
Monitor
1 Brightness
125IIIIIIII
2 Contrast 190IIIIIIII
3 Saturation
188IIIIIIII
4 Hue 133IIIIIIII
5 Live Refresh Rate Auto
6 Screen Center Point
7 Screen H-Size
8 Background Color
2
9 Show Color Bar
10 Exit
6.2.4 Date/ Time Position
This item allows you to move current Date/ Time Display to any position. Use the DIRECTION
buttons to move Date/ Time display.
6.2.5 PB Date/ Time Position
This item allows you to move the recorded Date/ Time Display to any position.
6.2.6 RS-485 Time Calibration
RS-485 is used for multi-point communications: many devices can be connected to the same
bus. Move to this item and press the ETNER button, all DVR-16/IP timers will be synchronized.
6.2.7 Call Monitor Dwell
The call monitor is always switching full screen video of all installed cameras, this item allows
you to set the Dwell Time between switching. The timer value ranges from 1 to 255 (the unit is
second).
6.2.8 Text Color
This item allows you to select one from 16 different colors for all display on the screen.
6.2.9 Display Type
This item allows you to select one from 6 different text types (reverse, bold…) for on Date/ Time
display.
6.2.10 OSD
This item allows you to select which information you want to display; you can choose from
1)T&D/T(camera title and date/time); 2)Title; 3)D/T(date/time); 4)OFF.
6.3.Monitor
This menu allows you to adjust the quality of the displayed image.
6.3.1 Video Setup
Item 1~4 involve adjusting the brightness, contrast, saturation and hue of attached cameras.
You may use the right/ left DIRECTION buttons to adjust the value.