Toshiba P600DL Projection Television User Manual


 
11
FUNCTION OF POWER PANEL
REAR OF CABINET INSIDE OF CABINET
(1)
OFF
O N
POWER
(3)
AC INLET
AC OUTLET
(2)
15A 125V/250V AC
AC100V-240V 50/60Hz
UNSWITCHED MAX 10A
No. Name Function Remark
1 Power Switch Turn ON and OFF main power ON/OFF
2 AC Inlet AC 100-240V, 50/60Hz input 3P plug
3 AC Outlet AC outlet, un-switched, max 10A 3P socket
Note 1: The AC outlet supplies un-switched power source to a second unit in a multi-projection
system. Do not use it for any other purpose. Serial connection using this power outlet must be
maximum four units including the 1st unit.
Note 2: The plug type of the projection unit power cable may not match the AC outlet. When power is
to be supplied to another unit from this AC outlet, please purchase necessary power cable.
Note 3: About Power Supply cord
The Power Supply cord must be in accordance with the applicable standards.
A three-core cord, one for ground, must be used.
The power cord must be at least 1.0mm
2
and H05VV-F.
POWER SWITCH AND POWER INDICATOR
AC power source is turned-on/off with the Power Switch. When the Power Switch is turned-on, the
Power Indicator lights in green color and a projection unit enters active state.
It takes about 30 seconds typically till an image is shown after Power Switch is turned-on.
In the active state, it is possible to power on/off with an external controller. When power is turned-off
with an external controller, the Power Indicator lights in red color and a projection unit enters
standby state.
Interval from turn-off to turn-on shall be more than 30 seconds. If the interval is not enough, the
lamp may not strike. If the user continues to do this, it may shorten the life of the lamp.
The power indicator indicates also failure information of the projection unit.
The later page at appendix list shows the lamp status.