5. Get-Function Listing
ThePCcaninterrogatetheLCDMonitorforspecicinformation.TheGet-Functionpacket
formatconsistsof5byteswhichissimilartotheSet-Functionpacketstructure.Notethatthe
“Value”byteisalways=00.
Get-Function description:
Length Total Byte of Message excluding “CR”
TV ID IdenticationforeachofTV.TheTVIDdoesn’tbesupportedbyHDTVpower
status on standby.
Command Type Identify command type,
“g”(0x67h):GetCommand
Command Functioncommandcode:OnebyteASCIIcode
Value[1~3] ThreebytesASCIIthatdenesthevalue
CR 0x0D
Get-Function format:
Send (Command Type= “g”)
Name
Length ID
Command
Type
Command
Value1
Value2 Value3
CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5 6 7 8 9
(Command Type= “g”, Only for HDTV power status on standby)
Name Length
Command
Type
Command
Value1
Value2 Value3
CR
Byte Count 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2 3 4 5 6 7
Reply: (Command Type= “r” or “-”)
If the Command is valid, Command Type = “r”
Name Length ID Command
Type
Command Value1 Value2 Value3 CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5 6 7 8 9
If the Command is valid, Command Type = “r”, Only for HDTV power status on standby.
Name Length Command
Type
Command Value1 Value2 Value3 CR
Byte Count 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2 3 4 5 6 7
If the Command is Not valid, Command Type= “-”
Name Length ID Command
Type
CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5