§ Table 5-1 outlines the Get-function command list that must be supported by the LCD
Monitor.
Table 5-1: PC Get-function command to LCD Monitor
Get Function Command
Code
(ASCII)
Command
Code
(Hex)
Response Range
(Three ASCII bytes)
Comments
Get-Contrast a 61 000 ~ 100 Gets Contrast value
Get-Brightness b 62 000 ~ 100 Gets Brightness value
Get-Sharpness c 63 000 ~ 100 GetsSharpnessvalue
Get-Color d
64
000 ~ 100 Gets Color value
Get-Tint
e
65 -50 ~ +50
Gets Tint value
Get-Volume f 66 000 ~ 100 Gets Volume value
Get-Mute g 67 000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF status
Get-Input select j 6A 000: TV
001:AV
002:SV
003: YPBPR
004: HDMI 1
005: HDMI 2
006:VGA
Gets Input select status
Get-Power status l 6C 000:STBY
001: ON
Gets the status of the HDTV power.
HDTV response:
000=HDTVisinstandby
001=HDTVisON
Get-Remote
Control
n 6E
000:DISABLE
001:ENABLE
002:PASS
THROUGH
Disable: RCU has no effect on HDTV.
Enabled: RCU controls the HDTV. This
is the power up default on the HDTV.
Pass through: RCU has no effect on
HDTV and all RCU command codes are
transmittedtoFCviatheRS232port.See
page 51 for more details
Get-Power Lock o 6F 000: Unlock
001: Lock
Get-Button Lock p 70 000: Unlock
001: Lock
Get-Menu Lock q 71 000: Unlock
001: Lock
Get-ACK z 7A 000 This command is used to test the
communication link.