ViewSonic VS13915-1M Flat Panel Television User Manual


 
43
Other Information
ENGLISH
ViewSonic VT3205LED
If the Command is Not valid, Command Type= “-”, Only for HDTV power status on
standby.
Name Length Command
Type
CR
Byte Count 1 Byte 1 Byte 1 Byte
Bytes order 1 2 3
Example1: Get power status on standby and this command is valid.
Send (Hex Format)
Name Length Command
Type
Command Value1 Value2 Value3 CR
Hex 0x36 0x67 0x6C 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name Length
Command
Type
Command Value1
Value2
Value3 CR
Hex 0x36 0x72 0x6C 0x30 0x30 0x30 0x0D
Example2: Get Brightness from TV-05 and this command is valid.
The Brightness value is 67.
Send (Hex Format)
Name Length
ID Command
Type
Command
Value1 Value2
Value3 CR
Hex
0x38
0x30
0x35
0x67
0x62 0x30
0x30
0x30 0x0D
Reply (Hex Format)
Name
Length
ID Command
Type
Command Value1
Value2
Value3 CR
Hex
0x38 0x30
0x35
0x72
0x62 0x30
0x36 0x37
0x0D
Example3: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name Length ID Command
Type
Command Value1 Value2 Value3 CR
Hex 0x38 0x30
0x35
0x67 0xD3 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name Length ID Command
Type
CR
Hex 0x34 0x30
0x35
0x2D 0x0D