Q-See QSF2648008 DVR User Manual


 
User Manual for Commercial Series Net DVR
Page 75 Total 121
Press “Confirm” you go back to “Recording” menu. Press “Confirm” again to save the
parameters and return to main menu.
Note:
1) If record type is “Motion Detect” or other related types, you must setup “Motion
Detection” in order to trigger motion recording (refer to chapter 5.10).
2) If record type is “Alarm” or other related types, you must setup “Alarms” in order to
trigger alarm recording (refer to chapter 5.13).
3) The time period is among 00:00—24:00.
6.13 External Alarm Input and Relay Output
For 8-channel DVR, there are 8 external alarm inputs and 4 relay outputs. For 16-channel
DVR, there are 16 external alarm inputs and 4 relay outputs. In “Alarms” menu, you can setup
each external alarm input.
In main menu, move “Active Frame” to “Alarms” icon and pressENTERkey to enter into
alarms menu:
External alarm input setup:
Step 1: Select one alarm input Use【↑】【↓】keys to select one alarm input.
Step 2: Alarm type
This is sensor type. You can select “Normal Open” or “Normal Close” according to the
sensor type.
Step 3: Enter into “Alarm in Handling” sub menu
In the “Alarms” menu, there are two options for “Alarm Handling” item. One is “Ignore”,