Setup
24 312759R
7. Press the Enter/Exit Screen button (GA) to exit the
screen.
Edit Auto-Sequencing
To edit whether the machine automatically performs all
shots in a sequence, use the following procedure.
1. Navigate to the Edit Screen that contains the
Sequence to be changed. See Screen Navigation
Diagram, page 16.
2. Press the Enter/Exit Screen button (GA) to enter the
screen.
3. Use the arrow keys to navigate to the Enable/Dis-
able Auto Sequencing Mode (GG) box for the
sequence position to be changed.
4. Press the Enter button ( ) to add or remove the
“X” from the box.
5. Navigate away from the Enable/Disable Auto
Sequencing Mode (GG) box to accept the change.
6. If Auto-Sequencing is enabled, the delay between
shots can be changed.
a. Navigate to the delay between shots (GF) for
the Sequence Position to be changed.
b. Use the numeric keypad to enter the desired
delay time in seconds.
c. Press the Enter button ( ) to accept the
delay and exit editing mode.
7. Press the Enter/Exit Screen button (GA) to exit the
screen.
F
IG. 12: Turn Auto-Sequencing On/Off
The delay shown in a given Sequence Position row
is the delay prior to beginning the next shot in the
sequence.
GA
GG
GF