Graco 312759R Home Theater Screen User Manual


 
Maintenance
68 312759R
Install Upgrade Token
This procedure applies to the Advanced Display
Module (ADM) and Fluid Control Module (FCM).
1. Disconnect power to the module.
2. Remove token access panel. See F
IG. 41.
3. Insert and press firmly token into slot.
NOTE: There is no preferred orientation of the token.
4. Restore power to the module. The red LED will flash
rapidly to signal that software is loading. When the
red LED stops flashing, the software is done load-
ing.
5. Disconnect power to the module.
6. Remove the token.
7. Replace token access panel.
8. Restore power to the module.
9. Repeat for each module that needs to be updated.
10. Verify new software versions on the System Data
Screen screen. See page 35.
F
IG. 41: Remove Access Panel
Advanced Display Module
ti12334a
ti12904a1
Fluid Control Module,
Low Power Temperature
Control Module