Graco 312759R Home Theater Screen User Manual


 
Setup
28 312759R
Heat Options, Screen #2
The Heat Options Setup Screen includes options for the
tank and hose heaters. Each tank and hose heater can
be enabled and disabled and each have their own set-
tings.
Zone Numbers
Each tank and hose heater is assigned to a specific
“zone” number. The zone number refers to the zone
number on the Integrated Heat Assembly. Each zone
number has a label above it. See F
IG. 16.
The zone number specified for each option on the Heat
Options Setup Screen needs to match how the system
is connected. For instance, if tank A is connected to
zone #1, then zone #1 needs to be selected for tank A
heat.
Temperature Settings
Each tank and hose heater has a high and low tempera-
ture alarm and a temperature setpoint. The tanks also
have a blanket heater temperature setpoint.
An alarm will sound when the material temperature is
outside of the range given by the high and low tempera-
ture setpoints. also, dispensing may be disabled
depending on the selections made in the System
Options Setup Screen, see page 30.
F
IG. 15
JA
Key:
JA Enter/Exit Screen
JB Enable/Disable Tank Heater Zone
JC Zone Number Used for Tank Heat Control
JD Tank Heat High Temperature Alarm
JE Tank Heat Temperature Setpoint
JF Tank Heat Low Temperature Alarm
JG Tank Heat Blanket Temperature Setpoint
JH Enable/Disable Hose Heater Zone
JJ Zone Number Used for Hose Heater Control
JK Hose Heater High Temperature Alarm
JL Hose Heater Temperature Setpoint
JM Hose Heater Low Temperature Alarm
JN Active Screen Name
JP Adjacent Screen Names
JR Active Screen Number
JS Adjacent Screen Numbers
JB
JC
JD
JE
JF
JH
JJ
JK
JL
JM
JG
JN
JP
JP
JS
JR
JS
FIG. 16: Integrated Heat Assembly, Zone Numbers
Zone #3
Zone #2
Zone #1
ti12593a
Zone #4
Assembly
LC0253 Shown