Graco 312759R Home Theater Screen User Manual


 
Troubleshooting
312759R 71
Error Codes
Code-Class-Event
Shown on Errors Screen Description
System
Behavior Ref
050X-A-Improper System Cal Improper Calibration 5
06CX-A-Invalid Key Token No or Invalid Key Token 4
A401-A-Over Current Z1 Heater Over Current, Zone #1 7
A402-A-Over Current Z2 Heater Over Current, Zone #2 7
A403-A-Over Current Z3 Heater Over Current, Zone #3 7
A404-A-Over Current Z4 Heater Over Current, Zone #4 7
A4C1-A-Fan Over Current Z1 High Relay 2 Current, Zone #1 7
A4C2-A-Fan Over Current Z2 High Relay 2 Current, Zone #2 7
A4C3-A-Fan Over Current Z3 High Relay 2 Current, Zone #3 7
A4C4-A-Fan Over Current Z4 High Relay 2 Current, Zone #4 7
A701-A-Heater Fault Z1 Unexpected Heater Current, Zone #1 7
A702-A-Heater Fault Z2 Unexpected Heater Current, Zone #2 7
A703-A-Heater Fault Z3 Unexpected Heater Current, Zone #3 7
A704-A-Heater Fault Z4 Unexpected Heater Current, Zone #4 7
A7C1-A-Fan Output Fault Z1 Unexpected Relay 2 Current, Zone #1 7
A7C2-A-Fan Output Fault Z2 Unexpected Relay 2 Current, Zone #2 7
A7C3-A-Fan Output Fault Z3 Unexpected Relay 2 Current, Zone #3 7
A7C4-A-Fan Output Fault Z4 Unexpected Relay 2 Current, Zone #4 7
B10X-A-Small Shot Request Less Than Minimum Shot Requested 5
CAC1-A-Comm. Error FCM 1 Communication Error, FCM3 #1 2
CAC1-A-Comm. Error FCM2 Communication Error, FCM3 #2 3
CAC1-A-Comm. Error Heat Z1 Communication Error, Heat Zone #1 1
CAC1-A-Comm. Error Heat Z2 Communication Error, Heat Zone #2 1
CAC1-A-Comm. Error Heat Z3 Communication Error, Heat Zone #3 1
CAC1-A-Comm. Error Heat Z4 Communication Error, Heat Zone #4 1
DEFX-A-Piston Timeout Piston Stroke Timeout 5
DJ0X-D-Linear Sensor Fault Bad Linear Position Sensor 6
F2A-Low Flow A Side Low A Side Fluid Flow, relative to calibra-
tion and user-input allowable variance.
See Dispense Check Options, Screen
#4 on page 31.
6