Honeywell
125
Please refer to the following sheet for detailed information.
Parameter Function
Event Type
There are three types: Motion detection/video loss/Camera
Masking.
Channel
Select channel name from the dropdown list, and check the
checkbox beside it to enable its motion detection function.
Sensitivity
There are six levels. The sixth level has the highest
sensitivity.
Region
There are six levels. The sixth level has the highest
sensitivity.
Region: If you select motion detection type, you can click
this button to set motion detection zone. The interface is
shown in Figure 6-40. There are PAL 22X18/NTSC 22X15
zones. Right-click and you can go to the full-screen display
mode. Do remember to click OK to save your motion
detection zone setup.
Period
Motion detection function becomes activated in the specified
periods.
There are six periods in one day. Please check the
checkbox to enable corresponding period.
Select date. If you do not, the current setup applies to today
only. You can select all week column to apply to the whole
week.
Click OK, and the system goes back to motion detection
interface; please click Save to exit.
Anti-dither Not Effective in the current DVR version.
Alarm out
There is 3-channel alarm output.
Corresponding to motion detection alarm output port
(multiple choices)
Enable alarm activation function. You need to select alarm
output port so that the system can activate the
corresponding alarm device when an alarm occurs.
Alarm latch
System can delay the alarm output for a specified time after
a detection event ends. The value ranges from 10s to 300s.
Record
channel
System auto activates motion detection channel (multiple
choices) to record once alarm occurs (working with motion
detection function). Please note you need to go to the
chapter Schedule on page 35 to set motion detection record
peri
od and go to the chapter Manual Record on page 27 to
set the current peri
od as auto record.
Record latch
System can delay the record for specified time after a
detection event ended. The value ranges from 10s to 300s.