Honeywell HREP8 DVR User Manual


 
60
Installation
2. Configure the following behavior settings:
3. Configure the following action settings:
Note Remember to select APPLY and click to save all settings before exiting
these menus.
Configuring Buzzer Out Settings
1. Click BUZZER OUT on the left side of the EVENT/SENSOR window.
The BUZZER OUT setup menu appears.
ALARM OUT Choose to configure a specific alarm output.
OPERATION Enable/disable the selected alarm output.
MODE Select from TRANSPARENT (the output is active only when the
trigger criteria are present) or LATCHED (the output is active for
a set period of time after a trigger).
DURATION In LATCHED mode, this is the time that the alarm output remains
active after it has been triggered.
TYPE Select from HIGH (0V to +5V when activated) or LOW (+5V to 0V
when activated).
HDD EVENT Determines whether a hard drive event triggers the alarm output.
ALARM Configure whether the alarm inputs trigger the alarm output.
VIDEO LOSS Configure whether video loss on any of the selected channels
triggers the alarm output.
MOTION Configure whether motion detection on any of the selected
channel triggers the alarm output.