12 KODAK Display Manager System V4.0 User’s Guide
Installing and Setting Up Your System
To connect the enable cable:
1. Disconnect the original monitor cable from the computer.
2. Attach the enable cable to the monitor port on the computer.
3. Connect the monitor cable to the enable cable.
4. Attach the USB connector of the enable cable to a USB port.
X-RITE Sensors
X-RITE Monitor Optimizer DTP94+EK (MonacoOPTIX)
Use this USB sensor on CRT or LCD monitors.
To position the sensor during calibration:
1. Attach the counterweight to the cable.
2. If using a CRT monitor, attach the suction cup to the sensor cable and
then fasten the suction cup to the screen.
IMPORTANT
Never use the suction cup on an LCD monitor.
USB connection
Enable cable connection
Monitor cable connection
Counterweight -
Attach to the
sensor cable to
counter balance
the sensor.
Suction cup -
Attach to the
cable and then
fasten the suction
cup to the screen.
Supports the
instrument's
weight when
using CRT
monitors.
Sensor - Hang in
front of the monitor
to measure
patches.
USB connection -
Connect to a USB
port on your