19
1-15-2 Direct Connection Information
Settings for the direct connection information are made from the extended
functions display. Direct connection information settings will not appear on
the extended function display unless direct connection is turned ON in the
Tool Settings.
Use the following procedure to set the direct connection information settings.
1, 2, 3...
1. Specify EXTEND from the Initial Edit Display. The following display will
appear at the bottom of the screen
2. Specify direct connection. (F-key is not supported by PTs with touch
panels and cannot be specified.) The following display will appear.
3. Set the direct connection information as described in the following table.
Item Setting
PT control area Set the address of the first word in the PC to be used to
control PT status. This setting must be made. A user
comment may also be input if desired.
PT notify area Set the address of the first word in the PC to be used to
store PT status. This setting must be made. A user
comment may also be input if desired.
Numeral mem. table The contents of the numeral table used in the file can be
seen in list form. Data can be input or changed.
String mem. table The contents of the character string table used in the file
can be seen in list form. Data can be input or changed.
F-key input/output notify Function keys cannot be set for PTs with touch panels.
These settings are not required and will be ignored if
input.
4. When the settings have been completed, press the Escape Key once to
return to the beginning of the operation and twice to end.
Direct Connection Section 1-15