Panasonic AJ-D92P VCR User Manual


 
52
Setup Menus
WARNING & ALARM menu
Item Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
The underlining indicates the factory setting.
900 BATT NEAR END
0000
0001
OFF
ON
For setting whether the warning alarm is to be sounded when the battery is
nearly totally discharged.
0: The warning alarm is not sounded.
1: The warning alarm is sounded.
901 BATT END
0000
0001
OFF
ON
For setting whether the warning alarm is to be sounded when the battery is
totally discharged.
0: The warning alarm is not sounded.
1: The warning alarm is sounded.
902 TAPE NEAR END
0000
0001
OFF
ON
For setting whether the warning alarm is to be sounded when the tape is
approaching the end.
0: The warning alarm is not sounded.
1: The warning alarm is sounded.
903 TAPE END
0000
0001
OFF
ON
For setting whether the warning alarm is to be sounded when the tape has
reached the end.
0: The warning alarm is not sounded.
1: The warning alarm is sounded.
904 TAPE WARNING
0000
0001
2min
3min
For setting the timing at which the warning alarm is to be sounded when the
tape is approaching the end.
0: The warning alarm is sounded 2 minutes before the tape reaches the
end.
1: The warning alarm is sounded 3 minutes before the tape reaches the
end.
905 TAPE REMAIN
0000
0001
3min
5min
For setting the remaining tape time indicated by one segment on the
remaining tape display.
0: Each segment is set to a remaining tape time of 3 minutes.
1: Each segment is set to a remaining tape time of 5 minutes.
906 ALARM SOUND
0000
0001
NORMAL
SIMPLE
For setting the tone of the warning alarm.
0: The warning alarm tone is changed according to the nature of the
problem.
1: The same warning alarm is sounded for all problems.