RCA PHD42600 Flat Panel Television User Manual


 
Other Information
32 Chapter 5
Graphics contained within this publication are for representation only.
Non-Operating
Temperature -5~45_
Relative humidity 20~80%
Pressure 700~1114hpa
Vibration X/Y/Z, 0.7G/30~50Hz(sweep), 15 minutes
Acoustics
(IHF A-weighted 1meter) 40dB Max.
Sound
Residual hum (at volume max) 500_W Max.
Practical max. Audio output (at 10% THD max.)
1.0vp-p 1K Hz input 5W +5W Max. / 4 ohm
Sound distortion (at 250 mw 1K Hz) 1% Max.
Audio output (input at 1.4V
P-P
) _1.0 V
P-P
Reliability Requirement
The MTBF needs 20000hrs under operation 25±5_(half luminosity, motion picture)
Emission Requirement
The unit shall meet the EMI limits in all screen modes. For EMI testing, the unit must be failed
with the screen pattern consisting of scrolling capital “H” characters also the brightness contrast
will be adjusted to max. level.
FCC class B part 15
Power Management
Mode H-sync V-sync Video Power dissipation
Normal Pulse Pulse Active Normal power
Stand-by No pulse No pulse No video Power off
Power Pulse No pulse blanked Less than 6 watts
saving No pulse Pulse
This Plasma display is Energy star compliant when used with a computer equipped with
DPMS.
Note: The power indicator LED color is green in normal state, yellow in stand-by and