Samsung SVR-24JP VCR User Manual


 
31 32
SERIES RECORDING
This is a convenient function in which when two or more VCRs are
connected the second unit starts recording when the tape on the first unit
reaches the end.
ALARM RECORDING
If the VCR is connected to equipment with an alarm output such as a frame switcher,
motion detector or door switch, the VCR will function according to the time and mode
selected on the ALARM REC menu when an alarm is received.
SVR-24JP has only L3H/L12H/L24H mode for ALARM REC.
The below diagram is set L3H mode for ALARM REC.
RECORDING
Connecting Operating Description
method method of operation
Refer to the
connection
method for
series recording
(page 37)
Select to No. 4 in the MENU
Select to "ON" for SERIES
using the SHIFT
!
and
button.
When the tape in the first unit
arrives at its end during
recording, the second unit begins
recording. When the tape in the
second unit arrives at its end and
during recording, the next unit
begins recording if connected.
When the series recording mode
is selected, the second unit
performs recording even if the
power is turned off.
As a constant alarm sounding,
you can clear it by only pressing
any key.
When pressing the RESET button
All the entered information such as reserve recording set
time, current time, and alarm information is erased.
The power is turned off, and there is no picture at all. When
the power is turned on again, flashes on the
display of the screen.
The current time is erased and must be reset.
RESET button
Use this button when the VCR or
display does not operate normally even
though the power is turned on.
The RESET button is on the right side of
the Front Panel.
Press the RESET button using a ball
point pen or a pencil.
REFERENCE
2001-1-1 MON
12:00:00 L3H
Connecting Operating Description of
method method operating
Connect the alarm
output equipment
as follows;
Select to MODE and
DURATION on
ALARM REC SETUP
in setting MENU3.
(Refer to ALARM
REC SETUP, page 16)
When connecting with
FRAME SWITCHER, it
is convenient, if the
switch is placed in
automatic position.
AUTO: The alarm recording time is
automatically determined by input of
the alarm signal. (1 minute)
20sec~5min: Alarm recording is made
for 20 seconds~5 minutes after input of
the alarm signal.
TAPE END: Alarm recording is made
up to the end of the tape after input of
the alarm signal.
When the alarm signal is entered, the
on the front display is turned on.
When the alarm recording is ended,
the on the front display flashes.
When you want to cancel the alarm
during alarm recording, make a
connection between the alarm release
and the alarm grounding for more than
0.5 second, when the alarm release is
entered, the alarm recording is
stopped.
When an alarm signal is received and
the BUZZER ON is selected in the
menu, the alarm sounds continuously.
To silence the buzzer, press any
button.
L12H~960H
(L12H~L24H)*
mode recording
L3H
mode recording
L12H~960H
(L12H~L24H)*
mode recording
L3H
mode recording
Timelapse recording
Start of
recording
Enter of
alarm signal
Enter of alarm reset
or over selected time
Enter of
alarm signal
Alarm recording Timelapse recording Alarm recording
1 2 3 4 5 6 7 8 9
10
1 2 3 4 5 6 7 8 9
10
IN
IN OUT
OUT
AUDIO
VIDEO
1
6
ALARM IN
TAPE END OUT
2
7
ALARM OUT
SERIES OUT
3
8
ALARM RESET
GND
4
9
ERROR OUT
SERIES IN
5
10
TRIGGER OUT
1 SHOT RECIN
GND
ALARM
OUT
ALARM
RESET
VIDEO
OUT
(Refer to page 37)
01671A SVR-24JP/960JP-E3 12/7/01 4:06 PM Page 32