Sony SVT-40E VCR User Manual


 
46
1 Turn on the power of the equipment to be used.
2 Press MENU and MENU
V
until “3” of the MAIN
MENU flashes on the monitor screen.
3 Press MENU
B
.
The ALARM SET menu appears.
4
Press MENU V to move the flashing to the setting
of
TAPE END WARN.
and set to
COUNTER or
TAPE END
by
pressing MENU + or –
.
5 Press SEARCH to return to the normal display.
SW OUT terminal
COM terminal
SW OUT Terminal
The VCR outputs a pulse signal from the SW (switch)
OUT terminal to the camera switcher to control the
switching from camera to camera.
A1
ALARM SET
ALARM MODE
ALARM SPEED 6H
20sec
ALARM DURATION
ALARM DATA REC
TAPE END WARN.
CLOG DETECTION
SERIES REC
SELECT : DATA SET :
+
/
RETURN : MENU
<
NEXT PUSH
>
OFF
COUNTER
ON
OFF
A1
ALARM SET
ALARM MODE
ALARM SPEED 6H
20sec
ALARM DURATION
ALARM DATA REC
TAPE END WARN.
CLOG DETECTION
SERIES REC
SELECT : DATA SET :
+
/
RETURN : MENU
<
NEXT PUSH
>
OFF
COUNTER
ON
OFF
Specify the interval between each pulse signal on the
DISPLAY SET/BUZZER/SW OUT menu. Also, set
MODE to FIELD or FRAME depending on the
specifications of the camera switcher.
Available settings are:
FIELD: 1, 2, 3, 4, 5, 10, 30, or 60 fields
FRAME: 1, 2, 3, 4, 5, 10, 30, or 60 frames
1 Turn on the power of the equipment to be used.
2 Press MENU and MENU
V
until “2” of the MAIN
MENU flashes on the monitor screen.
3 Press MENU
B
.
The DISPLAY SET/BUZZER/SW OUT menu
appears.
DISPLAY SET DATE ON
BUZZER ALARM IN ON
TAPE END ON
KEY IN OFF
SW OUT MODE FIELD
TIMING 01
6H MODE ON
TIME ON
SPEED ON
ALARM ON
WARNING ON
SELECT : DATA SET :
+
/
RETURN : MENU
<NEXT PUSH >
Terminals