SVM2608 Programming 37
Sample Rate, High-Speed (0xAC, 0xD4) — Read & Write
D15 – D9 Unused These bits are reserved for future use.
D8 – D0 SAMPRAT24 – 16
Sample Interval – These bits set the high speed sample rate.
Bit Weight = 8.333 ns/bit
Minimum Value = 6
Maximum Value = 2
24
– 1
Sample Rate, High-Speed (0xAE, 0xD6) — Read & Write
D15 – D0 SAMPRAT15 – 0
Sample Interval – These bits set the high speed sample rate.
Bit Weight = 8.333 ns/bit
Minimum Value = 6
Maximum Value = 2
24
– 1
Sample Points (0x10, 0x38, 0x60, 0x88, 0xB0, 0xD8) — Read & Write
D15 – D4 Unused These bits are reserved for future use.
D3 – D0 SIZE19 – 16
Waveform Capture Size - In Linear mode, this sets the number of data
points to be captured in a single sweep. In FIFO mode, this sets the
threshold for generating a service request interrupt or status bit. The
maximum size is 1 MSamples (2 Mbytes of data).
Sample Points (0x12, 0x3A, 0x62, 0x8A, 0xB2, 0xDA) — Read & Write
D15 – D0 SIZE15 – 0
Waveform Capture Size - In Linear mode, this sets the number of data
points to be captured in a single sweep. In FIFO mode, this sets the
threshold for generating a service request interrupt or status bit. The
maximum size is 1 MSamples (2 Mbytes of data).
Pre-Trigger Points (0x14, 0x3C, 0x64, 0x8C, 0xB4, 0xDC) — Read & Write
D15 – D4 Unused These bits are reserved for future use.
D3 – D0 PRE19 – 16
Size of Pre-Trigger Data – In Linear mode, this sets the number of data
points to be stored before the trigger occurs. In FIFO mode, this register
is not used.
Minimum Value = 0
Maximum Value = (Capture Size) – 1
Pre-Trigger Points (0x16, 0x3E, 0x66, 0x8E, 0xB6, 0xDE) — Read & Write
D15 – D0 PRE15 – 0
Size of Pre-Trigger Data – In Linear mode, this sets the number of data
points to be stored before the trigger occurs. In FIFO mode, this register
is not used.
Minimum Value = 0
Maximum Value = (Capture Size) – 1
Trigger Delay (0x18, 0x40, 0x68, 0x90, 0xB8, 0xE0) — Read & Write
D15 – D0 DELAY31 – 16
Trigger Delay - The trigger delay value is used to set the number of
samples between trigger occurrence and storing of data.
Minimum Value = 0
Maximum Value = 2
32
– 1