Asus TS100-E4/PI2 Home Theater Server User Manual


 
5-10 Chapter 5: RAID Conguration
5.2.6 Rebuilding the RAID
This option is only for the RAID 1, RAID 5 and RAID 10 sets.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID array failed, the sys-
tem displays the status of the RAID volume as “Degraded” during POST. You
can rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage
Manager RAID conguration.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press <Enter>, then use up/down arrow keys to select
the destination disk or press <ESC> to exit.
Select a destination disk with the same size as the original hard disk.
3. The utilty immediately starts rebuilding after the disk is selected. The
status of the degraded RAID volume is changed to “Rebuild”.
DEGRADED VOLUME DETECTED
“Degraded“ volume and disk available for rebuilding detected.
Selecting a disk initiates a rebuild. Rebuild completes in the
operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial# Size
3HDS722580VLSA80 VN6Bxxxx 76.7GB
[ ]- Previous/Next [Enter]- Selects [ESC]- Exit