WARNING
CAMCO’s Heavy Duty "E" Series Index Drives cannot be "hand cranked" when completely assembled, i.e. with follower
wheel installed. During some portions of repair, the motor drive package is used to rotate the input shaft and follower
wheel. Some means for running the motor at extremely low speeds is mandatory. Use extreme caution when operating
the motor during repairs.
Before starting disassembly of your CAMCO unit you should read and review the following instructions. These provide
important information on parts and procedures necessary to successfully complete your repair.
Comply with all WARNINGS and CAUTIONS!
Read the "Trouble Shooting Guide" section in your "General Service Manual" before disassembling CAMCO units.
CAMCO recommends the assistance of a CAMCO trained serviceman whenever repairs are more involved than replac-
ing oil seals or cam followers.
TORQUE REQUIREMENTS FOR TIGHTENING SCREWS:
The included table provides torque specification for US Standard and Metric Socket Head Cap Screw. Refer to
CAMCO’s "General Service Manual" for a complete listing of torque specification by grade and material.
US Standard Socket Head Cap Screw Metric Socket Head Cap Screw
Thread Size Torque (ft/lbs) Thread Size Torque (ft/lbs)
.250-20 12 M6 12
.312-18 24 M8 29
.375-16 45 M10 57
.500-13 110 M12 100
.562-12 150 M14 159
.625-11 210 M16 243
.750-10 380 M20 479
1.00-8 910 M24 811
1.125-7 1290 M30 1637
Torque values are for non-lubricated threads, coated only with a residual film of oil, as received from the manufacturer.
Values are for threads engaged 1.5 times the screw thread diameter and installed into steel parts.