EverFocus eDR1680 Series DVR User Manual


 
22
Post-Recording
Define the post-recording time (0~99 seconds) for corresponding camera. Default value is 10 Sec.
Alarm Output
To define which Alarm Output will be triggered when the Motion Action is triggered. Alarm Output
1,2,5,6 are NC type of signal, Alarm Output 3,4,7,8 are No type. Select N/A to disable alarm
output.Default value is 1 (alarm output 1).
Buzzer
To activate (ON) buzzer or not (OFF) while motion is triggered. Default value is “ON”.
Call Display
If Call Display function is enabled (ON), the call monitor will switch to the focus camera when the
Motion Action is triggered. Default value is “ON”.
Log
Log to event log list or not. Please refer to Event Log for the details. Default value is “ON”.
Show Message
To display the alarm message or not when the Motion Action is triggered. Default value is “ON”.
E-mail
To activate the E-mail notification function or not when the Motion Action is triggered. The E-mail
will be send to the defined receivers with an attached file, which contains the video graphic file f the
triggered moment. Please refer to E-Mail Configuration for detail setting. (Note)
Network Alarm
Reserved for the PowerCom (Optional) users. Please refer to the PowerCom user manual for the
detail information.
Note: If a new motion action is happened during the post record time from the previous
triggered motion, there will be no notification sending for the corresponding action.