Fluke VR101S Cable Box User Manual


 
VR101S
Users Manual
24
Event # column
The Event # column displays the number of each event.
The most recent events are displayed first. You may
have to scroll down (use the scroll bar on the right of the
window) to view all the events that the recorder has
recorded. The number 0 is given to an
open
event—an
event that is still in progress at the time that the events
were downloaded from the recorder.
Start Time column
The Start Time column displays the time that an event
started. The resolution of the time stamp in a recorder is
eight seconds. Therefore, if a transient occurred once
every second starting at 12:00:00, the first eight
transients would all be reported to have the same time
of 12:00:00. The next eight transients would be reported
as having the same time of 12:00:08. Also, if identical
information was downloaded twice from a recorder, the
two “identical” site reports could show a time difference
of eight seconds.
Event column
The Event column displays the types of events that
occurred.