or Cursor commands for code words:
“Framing”, “Address”, “Command” and
“Data”
Delete the entire command string to the
cursor position
Send the selected command string
Exit DiSEqC
TM
menu
Example of a user entry:
You wish to check the EXR 22 Kathrein matrix. The command
set for the EXR 22 matrix is E0 00 24 (LNB High) and E0 00 20
(LNB Low).
Calling up “DiSEqC
TM
”:
Press the
button
Press the
button to call up the user entry.
The data bits of the individual code words can now be entered using
the
to and to buttons.
Press the
button to send off the control command. The
symbol “>” indicates that the control command has been sent.
SAT-CTRL menu
DiSEqC
TM
menu
SAT
DiSEqC
TM
menu
See the technical appendix for DiSEqC
TM
command sets for
EXR 20, EXR 22 and 9xx series Kathrein matrices.