Kathrein MSK 125 Satellite TV System User Manual


 
63
DATA LOGGER
The Data Logger setting allows you to execute the stored
measurement device settings in a row and store the corresponding
measurement results.
For automatic measuring the stored device settings are used.
Up to 100 (00 ... 99) different measurement series can be stored.
Before using the “DATA LOGGER” function you must store the
required device settings in the “Store device settings” menu.
Note
The (Data Logger) button launches the
automeasure function.
Use the Up and Down buttons to go a page up or
down in the screen content.
The LC display displays the message “Press
MEMO EXPL for measurement results”.
During a measurement process you can use a maximum of
10 spectrum settings.
If you try to run more than 10 spectrum settings, the following
message will be displayed:
Spectrum Memory Full!
Only 10 Spec. Possible!
At this point the Data Logger stops its measurement.
TFT display
LC display
ENTERING THE START AND STOP LINE FOR AUTOMATIC MEASURING
...
Use the
button and the two-digit setting
storage number to select the start line where
automatic measuring is to start.
ENTERING THE START LINE FOR AUTOMATIC MEASURING