SAT
39 Write N1 Set port group 1 1
3A Write N2 Expansion option 1
3B Write N3 Expansion option 1
40 Read A0 Read analogue value A0 -
41 Read A1 Read analogue value A1 -
48 Write A0 Set analogue value A0 1
49 Write A1 Set analogue value A1 1
4F Write A7 Set analogue value A7 1
50 LO string Read current frequency -
51 LO now Read current frequency (table entry number) -
52 LO Lo Read Lo frequency (table entry number) -
53 LO Hi Read Hi frequency (table entry number) -
58 Write Freq Write channel frequency 2 or 3
59 Ch.No. Set selected channel number (receiver) 2
60 Halt Stop positioner -
61 Go E Move positioner eastward -
62 Go W Move positioner westward -
64 P Status Read positioner status register -
65 Read Pos Read positioner counter -
6C Goto Move positioner motor to “Counter value”, Hi, Lo 2
6D Write Pos Set positioner counter, Hi, Lo 2
COMMAND OVERVIEW FOR DATA BYTE
An appropriate data byte must only be sent id the command byte
requires data bytes. This can be seen in the above command byte
table. For more information on which data byte to send to which
command byte please refer to the speci cation of the device used.
Orbit
position
Polarisation
Switch Position
H/V
Switch Position
Low Band
Data Byte
1
VLoF0
VHiF1
HLoF2
HHiF3
2
VLoF4
VHiF5
HLoF6
HHiF7
3
VLoF8
VHiF9
HLoFA
HHiFB
4
VLoFC
VHiFD
HLoFE
HHiFF