Konica Minolta VI-300 Universal Remote User Manual


 
40
Chapter
2
File
Menu
9i
File – Import – Digitizer – One Scan (When VIVID 9i is Selected)
Parameters for [File-Import-Digitizer-One Scan-Option] Dialog Box
Scan Parameter
Mode
Standard
: The Filter settings are xed to H.Q. & N.F.
The settable distance range is from 600 to 1,000 mm.
The Gain value is xed at 0.
• Extend: The Filter settings are xed to Noise Filter (N.F.).
The settable distance range is from 500 to 2,500 mm.
• User: The Filter settings can be user-dened.
The settable distance range is from 500 to 2,500 mm.
Digitizer’s Parameter
GET
: Loads the setting parameters from VIVID 9i and uses them as parameters for this
command.
SET
: Saves the parameters set by this command to VIVID 9i as the setting parameters.
Number of Scans
Sets the number of shots to expand the dynamic range.
Increasing the number of shots reduces data loss.
Brightness
Checking this checkbox enables you to set the brightness of the image.
Use Color
Checking this checkbox takes a color shot when a scan is made.
Log
Performs log correction for the color data if this checkbox is checked. This correction is used to
make neutral colors brighter.
Dark
Performs dark correction for the color data if this checkbox is checked. This correction is used
when lines are noticeable in the color image.
Convert Parameter
Save Raw Data
Checking this checkbox displays the data save dialog at the end of the File-Import-Digitizer-
One Scan command, allowing you to save the data.
Reduction Rate
Used to select the number of data points to be read from “1/1”, “1/4”, “1/9”, “1/16” and “Adaptive”.
Filter • None: Performs no correction for points when reading data. This can be set for
User mode only.
• Noise Filter(N.F.): Reduces noise in points when reading data.
• High Quarity(H.Q.): Deletes low-reliable data when reading data.
• H.Q. & N.F.: Reduces noise in points and deletes low-reliable data when reading data.
Note
Inthecaseoflow-reliabledata,areaswithexcessivelyhighlaserpoweraredisplayedinlightgray,and
thosewithexcessivelylowlaserpoweraredisplayedindarkgray.
Fill Holes
If “ON” is selected, points are generated in the holes that were produced as a loss of data so that
the holes are lled.
Remove
Select the data to be deleted when reading data.
• None: Outputs the data without performing specic processing.
• Boundary (B.): Outputs the data after deleting boundary points.
• 5deg & B./10dwg & B./15deg. & B./20deg & B.:
Outputs the data after deleting the points present inside and at the bound-
ary of the polygons that are angled within approximately 5, 10, 15 and 20
degrees to the vector of the line of view.
Stage Parameter
Select the Port and Model to be used and click on the [Apply] button. The rotary stage will be
initialized. If initialization is successful, the rotary stage can be controlled by using the Angle
slide bar in the [File-Import-Digitizer-One Scan] dialog box.
Default
Restores the default parameter settings.
OK
Closes the [File-Import-Digitizer-One Scan-Option] dialog box.
The settings will be set.
Cancel
Closes the [File-Import-Digitizer-One Scan-Option] dialog box.
The settings will be cancelled.