Lennox Hearth G8 Satellite TV System User Manual


 
Option 3 - Connecting Three or More IRDs
(North American and Latin American Systems)
To connect three or four IRDs to the TracVision antenna, you will
need to install an active multiswitch (Channel Master model
6214IFD or equivalent) between the antenna and the IRDs. Two
RF cables should already be connected to the RF1 and RF2 plugs
on the base of the TracVision antenna. Figure 2-13 shows a typical
wiring arrangement for three or four IRDs. Mount the
multiswitch unit in accordance with the manufacturer’s
instruction sheet.
1. Connect the RF cable labeled "RF1" to the
multiswitch input labeled "LNB RHCP +13V.”
2. Connect the RF cable labeled “RF2” to the
multiswitch input labeled "LNB LHCP +18V.”
3. Connect the multiswitch outputs to individual IRD
inputs. Use RG-11 cable with F-type connectors for
all RF connections. Terminate all unused output
connectors with 75 ohm DC blocks (Channel
Master #7184, Radio Shack #15-1259 or equivalent).
54-0198
32
TracVision G8 Owner’s Manual - Guide to Technical Information
Figure 2-13
Single Multiswitch Installation
(North American and Latin
American Systems)
Multiswitch
DC In RHCP
+13v
VHF/UHF LHCP
+18v
Out 1 Out 2 Out 3 Out 4
DC Power
RF1 RF2
IRD #2 IRD #3
IRD #4
IRD #1
The use of an active multiswitch will
interfere with the 22 KHz tone sent
by DIRECTV DSS Plus
IRDs to
the antenna. As a result, the
antenna will not receive the signal
to change satellites when you
change channels using your
DIRECTV DSS Plus remote.