Memorex DVR H264 DVR User Manual


 
Network Stand Alone DVR
Network Stand Alone DVRNetwork Stand Alone DVR
Network Stand Alone DVR
Network (JPEG2000+H.264)
Network (JPEG2000+H.264)Network (JPEG2000+H.264)
Network (JPEG2000+H.264)
30
5-4. RECORD SETUP
This is the most important configuration of the DVR.
Enter into SYSTEM MENU-RECORD SETUP
and press the [ENTER] button.
RECORD SETUP
RECORD CONFIGURATION
SCHEDULE SETUP
HOLIDAY SETUP
SELECT MENU : ▲▼, & [ENTER]
1) RECORD CONFIGURATION
(1) OVERWRITE : Set overwrite or stop recording when
the HDD is full.
(2) MULTIPLEX
- DUPLEX : Playback & Ethernet
- TRIPLEX : Playback & Recording & Ethernet
Note: DUPLEX MODE is recommended to playback
the images at a maximum frame rate.
But, it makes DVR not to record during search.
(3) QUALITY : Set recording picture quality.
Actually it is fixing maximum data size of
image for each picture quality in 5 steps
as follows.
- BASIC
- NORMAL
- ENHANCED
- FINE
- SUPER FINE: Default quality set by manufacturer
In Emergency recording mode, recording quality is
SUPER FINE.
To send more images via IP network and longer recording
time, set QUALITY at NORMAL or ENHANCED and
record at 360x240(360x288).
Use direction button to move and [
-
] [+] button to set value.
(4) RESOLUTION : Set recording resolution.
- 120 ips at 720x240(NTSC) , 100 ips at 720x288(PAL)
- 240 ips at 360x240(NTSC) , 200 ips at 360x288(PAL)
- 480 ips at 360x120(NTSC) , 400 ips at 360x144(PAL)
It is not possible to see those images in full screen mode in playback.
Recording in Dual resolution is recommended for higher recoding speed, and also to send
more images via IP network.
(5) RECORD IN ALARM : Set record speed (skip rate) in ALARM record mode.
(6) RECORD IN MOTION : Set record speed (skip rate) in MOTION record mode.
(7) CONTINUOUS RECORD : Set record speed (skip rate) in CONTINUOUS record mode.
Set record speed (skip rate)
- 1/1x, 1/2x, ………. 1/999x record speed
- ex: 1/2x ) R->S->R->S… - ex: 1/3x ) R->S->S->R->S->S->R…
- ex: 1/4x ) R->S->S->S->R->S->S… ( R : RECORD S : SKIP )
- ex : If record resolution is set at 360x240, 1/1x = 240 ips, 1/2x = 120 ips, 1/3x = 80 ips, etc.
Data size of image in PAL system is a little bigger than NTSC system, but the total recording time
is same as in NTSC system.
RECORD CONFIGURATION
OVERWRITE
MULTIPLEX
QUALITY
RESOLUTION
RECORD IN ALARM
RECORD IN MOTION
CONTINUOUS RECORD
ON
DUPLEX
SUPER FINE
120IPS 720*240
1/1X
1/1X
1/1X
SELECT MENU : ▲▼, CHANGE VALUE : + -
CHAP. 5 Set Up