CHAP. 5 Set Up
- TIME OUT :
Adjust TIMEOUT value properly to
successfully access to DVMR unit via Internet
line. If data transmission speed is high enough,
leave TIMEOUT value as set by manufacturer
(200 msec), and increase it if data ansmission
via Internet line is relatively slow. Execute
tracert (Tracing Route) in your PC for IP
assigned to DVMR unit, and you can figure
out how much TIMEOUT value increased.
- RETRY COUNT :
Set the retry number of times for network
connection.
CONNECTION SETUP
TIMEOUT 200 MSEC
RETRY COUNT 08
SELECT MENU : ▲▼, & [ENTER]
DHCP SETUP
DHCP MODE
DNS SERVER
IP ADDRESS
SUBNET MASK
GATEWAY
AUTOMATAIC
168.126.063.001
192.168.001.086
255.255.255.000
192.168.001.001
SELECT : ▲▼, CHANGE VALUE : + -
(3) CONNECTION SETUP :
(2) DDNS SETUP :
- DDNS ON/OFF : Select if DDNS Function use
- DDNS SERVERS : IP Address of DDNS SERVER.
- INTERVAL : Registered time period to DDNS SERVER.
Per D (Day) H (Hour) M (Minute)
- REGISTER : Once press [ENTER],
It automatically registered.
- DDNS STATUS : present current status by
"REGISTER OK“
"REGISTER ERROR", "NOT REGISTER"
- IP ADDRESS : IP of last registered DVR
- IP PORT : Port of last registered DVR
- REMAIN TIME : Remain time to next registration
- LAST REG... DATA : Last registered time
DDNS SETUP
DDNS ON/OFF OFF
DDNS SERVER 211.062.253.087
INTERVAL D-00 H-00 M-20
REGISTER
--------------------------------------------------------------------------
DDNS STATUS
IP ADDRESS ---.---.---.---.---
IP PORT -----
REMAIN TIME D-00 H-00 M-00
LAST REGISTERATION DATE
>
SELECT MENU : ▲▼, & [ENTER]
- DHCP MODE : If user selects AUTOMATIC,
IP automatically assigned.
If user selects MANUAL, in IP CONFIG SETUP
User selects it manually.
- DETECT IP : It only appears for AUTOMATIC.
Once press [ENTER], it automatically starts IP
Assignment.
(4) DHCP SETUP :