Mitsubishi Electronics HS-S8300E(BRS) VCR User Manual


 
23
SETTING FOR ALARM RECORDING
1 Press the DISPLAY button to display MAIN MENU on the monitor.
2 Turn the JOG dial to select RECORDING SET UP
and turn the SHUTTLE ring to the right.
•“RECORDING SET UP menu will appear.
3 Turn the JOG dial to select ALARM REC MODE and
turn the SHUTTLE ring to the right.
4 Turn the JOG dial to set the alarm recording mode
and turn the SHUTTLE ring to the right.
5 Turn the JOG dial to select ALARM REC DURATION and
turn the SHUTTLE ring to the right.
6 Turn the JOG dial to set the alarm recording duration from 15 seconds to 10 minutes, MAN1 or
MAN2 (manual). When the desired setting is shown, turn the SHUTTLE ring to the right.
If the ALARM REC DURATION is set to MAN1, alarm recording will continue until a signal
is applied to the RST (RESET) IN terminal. If the signal applied to the RST (RESET) IN
terminal is within the first 15 seconds of alarm recording, alarm recording will continue for 15
seconds, then stop.
If the ALARM REC DURATION is set to MAN2, alarm recording will continue until the
signal applied to the SET IN terminal is removed. If the signal applied to the SET IN terminal
is removed within 15 seconds of the start of alarm recording, alarm recording will continue for
15 seconds, then stop.
The internal time clock can be adjusted if a signal is applied to the RST (RESET) IN terminal
on the rear panel when the ALARM REC DURATION is set to other than MAN1.
7 Turn the JOG dial to select EMERGENCY RECORDING and turn the SHUTTLE ring to the
right.
Turn the JOG dial to select ON.
8 Press the DISPLAY button.
The present time display will appear.
^ During alarm recording, the alarm recording count will automatically be displayed except when DISPLAY mode 4 is selected.
The alarm recording count display counts up to 9999 alarm recordings and then it is reset to 0000 and continues counting.
When initializing the alarm recording list, the alarm recording count display will be reset.
The alarm indicator flashes during alarm recording and lights up when the alarm recording is finished.
When the alarm recording is finished, the VCR resumes recording in the same record modes as before the alarm recording.
N
If a set signal is applied during alarm recording, a new alarm recording will start with the new set signal. Should one SET signal
be applied within 15 seconds of another, the later SET signal will be ignored and a new alarm recording will not take place.
Alarm recording will continue for the duration of time which has been set in the ALARM REC DURATION menu, even if a timer
recording has reached its end time.
Alarm recording stops when the end of the tape is reached.
EMERGENCY RECORDING
Emergency Alarm Recording can start recording when an Alarm is triggered even if the VCR is off, stopped or in Timer Recording/
Stand-by. Turn the JOG dial to select EMERGENCY RECORDING and turn the SHUTTLE ring to the right.
Turn the JOG dial to select ON to select Emergency Recording, or OFF to disable it.
•“EMGCY lights up on the fluorescent display when the EMERGENCY REC of the RECORDING SET UP menu is set to ON.
<
MAIN MENU
>
DISPLAY
TIME DATE SEARCH
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE
FIRST TIME SET UP
Use JOG to select,
and ENTER.
Press DISPLAY to exit.
<
RECORDING SET UP
>
3H
1M
OFF
ALARM REC MODE
ALARM REC DURATION
EMERGENCY REC
<
RECORDING SET UP
>
3H
1M
OFF
ALARM REC MODE
ALARM REC DURATION
EMERGENCY REC
<
RECORDING SET UP
>
3H
1M
ON
ALARM REC MODE
ALARM REC DURATION
EMERGENCY REC
Alarm Recording is used to activate more rapid recording when the VCR is recording in one of the Time Lapse modes. Alarm Recording
provides for more pictures during the Alarm duration. Emergency Recording enables Alarm Recording even if the VCR is off, stopped
or in Timer Recording/Standby. You should set the Alarm Recording mode with the RECORDING SET UP menu before Alarm
Recording is used.