Mitsubishi Electronics HS-S8300E(BRS) VCR User Manual


 
39
CONTROL INPUT/OUTPUT SIGNALS AND CIRCUITS
2 SET/ RST/ REC IN terminals (screw) Active:
When input terminals are short-circuited to GND or L level voltage (0 - +1.6V) applied.
Time for active: 0.1 sec or over.
Non active: Open the input.
DC5V
GND
SET/RST/REC IN
0.047µF
22k
10k
<Interface circuit inside the VCR>
2 ALM/ MODE/CALL OUT terminals (screw) Active: L level voltage (0 - +0.4V) output; max. drive current 50mA(+5V DC)/
10mA(+24V DC)
Non active: Open; max. voltage +24V DC
GND
ALM / MODE/ CALL OUT
<Interface circuit inside the VCR>
2 CLK OUT terminal (screw)
<Interface circuit inside the VCR>
10k
DC12V
CLK OUT
10k
GND
CLK OUT signal
When F is selected in REC of CLOCK OUT mode in 3H recording.
+12V
0V
20msec
When except F is selected in REC of CLOCK OUT mode in 3H recording.
+12V
0V
8msec
During recording in L12H - 960H recording mode.
+12V
0V
10msec