Mitsubishi Electronics HS-S8300E(BRS) VCR User Manual


 
24
LOCATING THE START OF ALARM RECORDINGS
This machine automatically inserts an index signal at the beginning of each ALARM RECORDING, allowing the start of each alarm
to be located.
^ INDEX SEARCH
During fast forward or rewind the machine will search for index signals. When an Index signal is found, the VCR will playback the
tape and stay in still mode.
1 Press the COUNTER MEMORY/SKIP/INDEX button to illuminate INDEX on the fluorescent display.
(On the fluorescent display INDEX will be illuminated and the number indication will be illuminated.)
2 Turn the JOG dial to display the number (1-15) corresponding to the alarm index you desire to locate.
3 Turn the SHUTTLE ring to the right (forward direction) or left (reverse direction).
(The program indication number will decrease one by one as each index signal goes by.)
The index signal may be difficult to locate in some recording conditions.
^ SKIP SEARCH
The VCR will fast forward or rewind until an index signal is located and then playback for about 4 seconds in 3H mode. This process
is repeated until the end or beginning of the tape is reached.
-15
-1
+1
+2
+15
ALARM
RECORDING
ALARM
RECORD-
ING
ALARM
RECORDING
ALARM
RECORDING
ALARM
RECORDING
Present position
Rewind direction
Fast forward direction
1 Press the COUNTER MEMORY/SKIP/INDEX button to illuminate
SKIP on the fluorescent display.
2 Turn the SHUTTLE ring to the right or left.
ALARM
RECORDING
ALARM
RECORDING
Present position
Index
Fast forwardFast forward
Index
Approx. 4 sec.
playback
Approx. 4 sec.
playback
Fast forward
Until the index signal is located, the machine will fast forward (or rewind). When an index signal is located, the machine will playback
(in 3H mode) for about 4 seconds. This process will be repeated until the end or the beginning of the tape is reached.
When the desired position is located, press the PLAY button.
To stop SKIP SEARCH, press the STOP button.
The index signal may be difficult to locate in some recording conditions.
ALARM RECORD TIME DISPLAY
When alarm recordings begin, the start times are stored in memory, so it is possible to confirm when they
have occurred. Select the ALARM LIST in the MAINTENANCE menu and the alarm list display will
appear on the screen.
Up to 3 alarm recording start times can be stored in memory. For more than that, the first and the last 2
times will be displayed.
The alarm recording list is reset by the following procedure.
1. Select the ALARM LIST CLEAR in the MAINTENANCE menu.
2. Turn the SHUTTLE ring to the right. ALARM LIST CLEAR will be displayed.
3. Turn the SHUTTLE ring to the left. ALARM LIST will be cleared.
<
ALARM LIST
>
0001 05 - 01 - 99 01 : 00
0002 07 - 01 - 99 21 : 10
0003 10 - 01 - 99 09 : 15
ALARM RECORDING