40
POWER/STANDBY
INPUT SELECT VOLUME
PlasmaSync 4210W
External equipment
e.g., Personal computer
Running Sense
Running Sense
Running Sense
Communications Flow
The PlasmaSync 4210W regularly transmits a Running Sense command at an interval of approximately 1 second.
(Running Sense command: 1FH 60H E0H 88H 00H E7H)
This command is used to recognize optional equipment. The return of an ACK is not required when external equipment
such as a personal computer has been connected.
Note that destruction of this data is recommended when it is taken in.
When various commands are to be sent from external equipment such as a personal computer, the PlasmaSync 4210W is
always receive enabled.
Note that when an ACK has not been returned from the PlasmaSync 4210W in 1.5 seconds, a resending of the command
is recommended.