NEC 4210W Flat Panel Television User Manual


 
44
10. TINT Gain Data
Function
The external control equipment changes the TINT gain data of the PlasmaSync 4210W.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: TINT Gain Flag 05H
DATA02: TINT Gain EAH: -22
FFH: -01
00H: 0
01H: +01
16H: +22
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: TINT Gain Flag 05H
11. SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the PlasmaSync 4210W.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: SHARPNESS Gain Flag 06H
DATA02: SHARPNESS Gain F0H: -16
FFH: -01
00H: 0
01H: +01
10H:+16
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: SHARPNESS Gain Flag 06H
12. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the PlasmaSync 4210W.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: CONTRAST Gain Flag 07H
DATA02: CONTRAST Gain 00H : 0
34H: +52
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: CONTRAST Gain Flag 07H