Panasonic AJ-D455P VCR User Manual


 
43
Rack mounting
The unit can be mounted into a 19-inch standard rack if the optional rack-mounting adaptors
(AJ-MA75P) are used. For the installation rails, it is recommended that the rail and bracket
for 18" length (model number CC3061-99-0400) of Chassis Trak be used. (The complete
slide rail and bracket unit is not available from Panasonic.) For further details, consult with
your dealer.
1
Refer to below for the places where they are to be secured with the screws.
A B CDEFG H
Attach the inner members at the
same symmetrical positions on the
left (L) side.
Note: The letters A to H are not
actually marked on the side
panels.
Inner member
Locations where the screws are secured on right (R)
side of inner members of slide rails
The length of the screws used is subject to restriction. Use screws which are less than
2/5" long in their place.
6 screws must be used to secure each inner member.
2
Attach the outer member brackets to the rack.
Check that the height is the same for the left and right brackets.
3
Remove the four screws at the front for attaching the left and right side panels.
4
Attach the AJ-MA75P rack mount adapter using the 4 screws included.
Rack-mounting adaptors
5
Remove the 4 rubber legs from the bottom of the unit, and install the unit in the rack.
After the unit has been installed, check that it moves smoothly along the rails.
Fasten it to the
rack with set
screws.
EIA standard rack
<Notes>
Keep the temperature inside the rack to between +41°F (5°C) and +104°F (40°C).
Bolt the rack securely to the floor so that it will not topple over when the VTR is drawn out.