Panasonic PT-DZ21KE Home Theater Screen User Manual


 
[PROJECTOR SETUP] menu
ENGLISH - 103
Settings
10)
Press

to select [CALIBRATION
TIME].
11)
Press the <ENTER> button.
12)
Enter the time and press the <ENTER>
button
z
Measure brightness at a specied time.
Dynamic iris is xed to open during
measurement.
13)
Press

to select [CALIBRATION
MESSAGE].
14)
Press
󱚣󱚤
to switch [CALIBRATION
MESSAGE].
z
The setting will change as follows each time
you press the button.
[ON] [OFF]
[ON]
Displays a message during
calibration.
[OFF]
Does not display a message during
calibration.
15)
Press

to select [APPLY].
16)
Press the <ENTER> button.
z
The set [MODE] and [LINK] are enabled, and
LAMP RELAY screen alert is displayed when
the [LAMP RELAY] setting is [OFF]. When
[CALIBRATION MESSAGE] is set to [ON], a
calibration running message is displayed which
will automatically disappear 30 seconds after
calibration completes.
z
If the [MODE] in [BRIGHTNESS CONTROL
SETUP] is not [OFF] when the <ENTER>
button is pressed, the lamp brightness at that
time is recorded as the standard brightness.
z
If the <ENTER> button is pressed when [LINK]
is [GROUP A] to [GROUP D], the group name
is displayed on the projector screen set as the
same group.
/,1. *5283$
Note
z
When setting the [MODE] in [BRIGHTNESS
CONTROL SETUP] to [AUTO] or [PC], [APPLY]
luminance control after the shutter is open for at
least two minutes.
z
If the shutter is closed within approx. 10 minutes
from the time that the lamp turns on when operating
with the [MODE] in [BRIGHTNESS CONTROL
SETUP] set to [AUTO] or [PC], brightness may be
corrected approx. two minutes after the shutter
opens because brightness could not be measured.
z
When operating with the [MODE] in [BRIGHTNESS
CONTROL SETUP] set to [AUTO] or [PC], lamp
brightness is automatically measured eight minutes
after a lamp is turned on, and corrected to the same
value as the screen brightness and the standard
brightness at the time of [APPLY]. Lamp brightness
cannot be measured during the eight minutes after
it is turned on because it is not steady.
z
When [LAMP SELECT] is 2 lit or higher and the
[MODE] in [BRIGHTNESS CONTROL SETUP] is
operating in [AUTO] and a light fails to turn on or
LAMP RELAY is performed, brightness is corrected
one minute later whenever possible.
z
When operating with [MODE] in [BRIGHTNESS
CONTROL SETUP] set to [AUTO], and [LINK] is
[OFF], brightness correction is performed until
correction exceeds the maximum correction
amount.
z
In certain projector environments, dust may
accumulate on the lens or screen or inside the
projector and increase variation in brightness.
z
Adjust luminance control again when lamp
degradation causes increased variation in
brightness or a lamp is replaced.
z
For continued use longer than 24 hours, set
the [BRIGHTNESS CONTROL SETUP] to
[CALIBRATION TIME], or set [LAMP RELAY]
(
page 101). Correction is not automatically
executed when not set.
z
Luminance control and iris operate simultaneously,
but the iris does not operate when fully open while
a brightness measurement is performed.
z
The setting of [CALIBRATION TIME] applies at the
time when the time is entered.
z
The setting of [CALIBRATION MESSAGE] applies
at the time when the item is switched with
󱚣󱚤
.