Troubleshooting
6-4
9123-A2-GB20-00
May 2000
Restoring Communication with a Misconfigured Unit
Misconfiguring the unit could render the menu-driven user interface inaccessible.
If this occurs, connectivity to the unit can be restored via a directly connected
asynchronous terminal.
" Procedure
To reset COM port settings:
1. Configure the asynchronous terminal to operate at 19.2 kbps, using character
length of 8 bits, with one stop-bit, and no parity. In addition, set Flow Control
to None.
2. Reset the unit, then hold the Enter key down until the System Paused screen
appears. (See
Resetting the Unit and Restoring Communication
for other
methods of resetting the unit.)
3. Tab to the desired prompt, and type y (Y
es) at one of the prompts.
If selecting . . . The following occurs . . .
Reset COM Port usage H Port Use is set to Terminal so the
asynchronous terminal can be used.
H Data Rate (Kbps), Character Length, Stop Bits,
and Parity are reset to the factory defaults.
H Unit resets itself.
Reload Factory Defaults H All configuration and control settings are reset
to the Default Factory Configuration,
overwriting the current configuration.
H Unit resets itself.
CAUTION: This causes the current configuration
to be destroyed and a self-test to be performed.
If no selection is made within 30 seconds, or if No (n) is entered, the unit
resets itself and no configuration changes are made.
Once the unit resets itself, connectivity is restored and the Main Menu screen
appears.