5.13 External Alarm Input and Relay Output
For DVR-470, there are 4 external alarm input and 2 relay output. For DVR-1670, there are
16 external alarm input and 4 relay output. In “Alarms” menu, you can setup for each
external alarm input. In main menu, move “Active Frame” to “Alarms” icon and press
ENTERkey to enter into alarms menu
External alarm input setup
Step 1Select one alarm input
Use【↑】【↓】keys to select one alarm input.
Step 2Alarm type
This is sensor type. You can select “Normal Open” or “Normal Close” according to the
sensor type.
Step 3Enter into “Alarm in Handling” sub menu
In the “Alarms” menu, there are two options for “Alarm Handling” item. One is “Ignore”,
and the other is “Handle”. If you select “Handle” option, you can active “Policy” and “PTZ
Linkage” buttons on right side. Move “Active Frame” to “Policy” button and pressENTER
key, you will enter into “Alarm in Handling” sub menu