Connection with RS-485
Remote control is allowed through connection with RS-485 (up to 1.2km).
A. Communication method
Data transmission method: Start-Stop Synchronized Serial Interface
Protocol: 8 bit Data, 1 Stop bit, None Parity
Transmission speed: 4800, 9600, 19200, 38400 bpss
B. RS-485 terminal and Pin specifications
C. Data Format (Samsung Protocol)
DATA +
DATA -
9 Byte Fixed
( ) : Byte numbers
Start Code (A0H)
(1)
Data Byte Type Contents Remarks
Byte 1 Start Code 0xA0 Start of Data Packet
Byte 2 Sender Addr. Transmission Address Source Range (0x00 ~ 0xFF)
Byte 3 Target Addr. Reception Address Destination Range (0x00 ~ 0xFF)
Byte 4 Only Image Recorder Command 0x0A
Byte 5 Key Function Range (0x01 ~ 0xFF)
Byte 6 Command 0xFF 0xFF
Byte 7 0xFF 0xFF
Byte 8 0xFF 0xFF
Byte 9 Check Sum Lower byte of (0xFFFF - (values adding Byte 2 ~ Byte 8))
Start Addr.
(1)
Target Addr.
(1)
Command
(5)
Check Sum
(1)
D. Code value by key
Function Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6, 7, 8 Byte 9
Response
(Byte 5)
[SET COMMAND]
MENU 0xA0 Src.Addr Dest.Addr. 0x0A 0x01 0xFF Check Sum 0x01
SEARCH 0xA0 Src.Addr Dest.Addr. 0x0A 0x02 0xFF Check Sum 0x02
SET/STILL 0xA0 Src.Addr Dest.Addr. 0x0A 0x03 0xFF Check Sum 0x03
UP 0xA0 Src.Addr Dest.Addr. 0x0A 0x04 0xFF Check Sum 0x04
DOWN 0xA0 Src.Addr Dest.Addr. 0x0A 0x05 0xFF Check Sum 0x05
LEFT 0xA0 Src.Addr Dest.Addr. 0x0A 0x06 0xFF Check Sum 0x06
RIGHT 0xA0 Src.Addr Dest.Addr. 0x0A 0x07 0xFF Check Sum 0x07
PLAY 0xA0 Src.Addr Dest.Addr. 0x0A 0x08 0xFF Check Sum 0x08
STOP 0xA0 Src.Addr Dest.Addr. 0x0A 0x09 0xFF Check Sum 0x09
RECORD 0xA0 Src.Addr Dest.Addr. 0x0A 0x0A 0xFF Check Sum 0x0A
REC LOCK 0xA0 Src.Addr Dest.Addr. 0x0A 0x0B 0xFF Check Sum 0x0B
F.Shuttle 1 0xA0 Src.Addr Dest.Addr. 0x0A 0x0C 0xFF Check Sum 0x0C
F.Shuttle 2 0xA0 Src.Addr Dest.Addr. 0x0A 0x0D 0xFF Check Sum 0x0D
F.Shuttle 3 0xA0 Src.Addr Dest.Addr. 0x0A 0x0E 0xFF Check Sum 0x0E
F.Shuttle 4 0xA0 Src.Addr Dest.Addr. 0x0A 0x0F 0xFF Check Sum 0x0F
F.Shuttle 5 0xA0 Src.Addr Dest.Addr. 0x0A 0x10 0xFF Check Sum 0x10
F.Shuttle 6 0xA0 Src.Addr Dest.Addr. 0x0A 0x11 0xFF Check Sum 0x11
F.Shuttle 7 0xA0 Src.Addr Dest.Addr. 0x0A 0x12 0xFF Check Sum 0x12
F.Shuttle 8 0xA0 Src.Addr Dest.Addr. 0x0A 0x13 0xFF Check Sum 0x13
R.Shuttle 1 0xA0 Src.Addr Dest.Addr. 0x0A 0x14 0xFF Check Sum 0x14
R.Shuttle 2 0xA0 Src.Addr Dest.Addr. 0x0A 0x15 0xFF Check Sum 0x15
R.Shuttle 3 0xA0 Src.Addr Dest.Addr. 0x0A 0x16 0xFF Check Sum 0x16
R.Shuttle 4 0xA0 Src.Addr Dest.Addr. 0x0A 0x17 0xFF Check Sum 0x17
R.Shuttle 5 0xA0 Src.Addr Dest.Addr. 0x0A 0x18 0xFF Check Sum 0x18
R.Shuttle 6 0xA0 Src.Addr Dest.Addr. 0x0A 0x19 0xFF Check Sum 0x19
R.Shuttle 7 0xA0 Src.Addr Dest.Addr. 0x0A 0x1A 0xFF Check Sum 0x1A
R.Shuttle 8 0xA0 Src.Addr Dest.Addr. 0x0A 0x1B 0xFF Check Sum 0x1B
R.JOG 0xA0 Src.Addr Dest.Addr. 0x0A 0x1C 0xFF Check Sum 0x1C
F.JOG 0xA0 Src.Addr Dest.Addr. 0x0A 0x1D 0xFF Check Sum 0x1D
E. Others
Above data format and transmission speed may be changed depending on future
development conditions.
PC operates as Master, and Target Set as Slave in transmission/reception of data.
No status other than Set Key Function should be received. Provided, however, that con
tents recorded in a set should be always received for alarm function
(Some delay can be happen due to communication speed).