Samsung SMT-190Dx DVR User Manual


 
2-5) External terminal connecting
method for Camera and
Monitor
1) External terminal connecting method for
CAMERA
PIR Sensor
Camera alarm injack
Sensor
input
Sensor
An additional PIR sensor or external sensor can
also be connected.
The additional PIR sensor can be connected as
shown in the above graphic.
Sensor’s trigger signal is NO (Normal Open).
Sensor is not supplied. (Sold separately)
2) ALARM terminal connecting method.
<SMT-190DN>
<External Recorder>
a.
Connect the A/O (HOT) terminal on the rear panel
to the Alarm IN terminal of the VCR.
b. Connect the A/O (COLD) terminal on the rear
panel to the Ground terminal of the VCR.
c. Connect the A/R terminal on the rear panel to the
Alarm Reset terminal of the VCR.
d. Connect the G (ground) terminal on the rear panel
to the Ground terminal of the VCR.
Total System Conguration
MONITOR
SMT-190DN
MONITOR
SMT-190DN
Local System Conguration
MONITOR
SMT-190DN
Eng-12
USER'S MANUAL