Samsung SMT-190Dx DVR User Manual


 
5-4) DWELL TIME SETUP
The initial setup status of DWELL TIME SETUP menu is
shown below.
07/07/07 12:30:01
DWELL TIME SETUP
CAM1 03 SEC
CAM2 03 SEC
CAM3 03 SEC
CAM4 03 SEC
CAM5 03 SEC
CAM6 03 SEC
CAM7 03 SEC
CAM8 03 SEC
QUAD-A 03 SEC
QUAD-B 03 SEC
1. DWELL TIME SETUP
- Pressing SEQUENCE button in Single Screen will
bring up the SEQUENCE MODE. You may set the
time display for each channel. If you set zero (0)
seconds as the DWELL TIME for a particular
channel, the set channel will be skipped and next
channel will be shown. You may set time in the
QUAD-A, QUAD-B screens.
[0SEC, 1SEC, 2SEC, 3SEC.................... ~ 60SEC]
- Use
,
,
,
, key to make changes.
5-5) ALARM SETUP
• Function: Allow users to set the ALARM MODE for
each camera.
• Setting method: Move to ALARM SETUP MENU by
using
/
KEY in the SETUP MENU, and press the
ENTER SWITCH to display the OSD as shown in the
gurebelow.(Thegureshowstheinitialsettingstatus.)
07/07/07 00:00:01
ALARM SETTING
CAMERA1 ON
CAMERA2 ON
CAMERA3 ON
CAMERA4 ON
CAMERA5 ON
CAMERA6 ON
CAMERA7 ON
CAMERA8 ON
HOLD TIME 05SEC
ALARM ON TIME 00:00
ALARM OFF TIME 00:00
ALARM TONE ON
(1) CAM1 to CAM8 item sets whether the alarm sensor
connected to the camera is used or not.
(ON: Alarm function setting, OFF: Alarm function
canceling)
(2) HOLD TIME item sets time to freeze alarm operation
when alarm occurs.
(HOLD TIME to be set: 05SEC ~ 1MIN ~ 30MIN)
Note
If you want to carry out the alarm operation, you must
preset ALARM ON/OFF TIME in monitor before
CAMERA ALARM is set to ON.
(3) ALARM TONE sets whether or not alarm tone
(high-pitched tone)sounds when an ALARM occurs.
(ON: ALARM TONE operation, OFF: Cancel)
5-6) EVENT RECORD MODE
The initial setup status of EVEVT RECORD SETUP
menu is shown below.
07/07/07 00:00:01
EVENT RECORD SEUTP
EVENT RECORD ENABLE
OFF
PRE ALARM TIME LIMIT
0 SEC
POST ALARM TIME LIMIT
1 MIN
MOTION DETECTION
OFF
SENSITIVITY
NORMAL
MOTION CH SETUP...
1. EVENT RECORD ENABLE
If you want to start recording when Alarm goes off,
then select ON. If you do not want to start recording
when Alarm goes off, then select OFF. If you set
EVENT RECORD ENABLE to ON and exit the menu,
system starts recording whenever Alarm is activated.
The following screen shows that ALARM recording is
in progress when ALARM is activated.
It shows the ALARM for Channel 4 is activated with a
"A" mark. [ON/OFF]
07/01/05 00:00:01
CAM1 CAM2 CAM3
A CAM4 CAM5 CAM6
CAM7 CAM8
USER'S MANUAL
Eng-21
USER'S MANUAL