English
Recording settings
61 How to set
1
Display the <ALARM OPERATION SET> screen as
explained in "Displaying the recording settings
screen", and then turn the S-dial clockwise. (P39)
The "OFF" indicator of ALARM RETRIGGER starts
blinking.
2
Turn the J-dial, select "ON" for ALARM
RETRIGGER, and turn the S-dial clockwise.
The cursor moves to "MAIN MON. DISPLAY".
3
Press the EXIT/OSD button when the settings are
complete.
Operation returns to the normal screen.
1
Turn the J-dial, select "MAIN MON. DISPLAY", and
turn the S-dial clockwise.
Selections: FULL/9/16/NC
The "FULL" indicator of MAIN MON. DISPLAY starts
blinking.
2
Turn the J-dial to select FULL (example), and then
turn the S-dial twice clockwise.
Selections: LAST/FIRST/SWITCH
The "LAST" indicator of ALARM PRIORITY starts
blinking.
3
Turn the J-dial to select "FIRST", and then turn the
S-dial twice clockwise.
The "NC" indicator of MON.2 DISPLAY starts blinking.
4
Turn the J-dial, select "LAST", and then turn the
S-dial clockwise.
The cursor moves back to the ALARM RETRIGGER
field.
5
Press the EXIT/OSD button when the settings are
complete.
Operation returns to the normal screen.
b Alarm cancellation
• Forced cancellation of an alarm operation in progress
Press the camera selection button of the channel with the
alarm for about 3 seconds.
• Cancellation by a switch when alarm is detected
Install a switch between the ALARM RESET and the C
(ground) terminal of the terminal block on the rear panel,
and turn on the switch when an alarm is detected.
H-1 Alarm operation settings
MENU
(J)
(S)
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
8.ALARM OPERATION SET
2.RECORD SET
<MAIN MENU>
<RECORD SET>
EXIT/OSD
H-2 Alarm display settings
(J)
(S)
<ALARM OPERATION SET>
ALARM RETRIGGER : OFF
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
EXIT/OSD
C
ALARM RESET