Sanyo DSR-3709PA DVR User Manual


 
English
General settings
71 How to set
The protocol (address) and the external alarm trigger
control settings are needed when operating the coaxial
superimposed dome camera.
If the protocol settings are set to "OFF" the "ALARM REC
TRIGGER SET" cannot be set.
1
Connect the VIDEO IN terminal on the rear panel of
the DVR to a remotely controllable dome camera
using a coaxial cable. (Figure 1)
2
Display the <CAMERA CONTROL SET> screen as
explained in "Displaying the general settings
screen" (P62).
3
Turn the J-dial to select "PROTOCOL/ADDRESS
SET" and then turn the S-dial clockwise.
The <PROTOCOL/ADDRESS SET> screen is
displayed.
4
Turn the J-dial to move the cursor to the channel
number (example: 06) of the VIDEO IN terminal
where the camera is connected to the rear panel of
the DVR, and then turn the S-dial clockwise.
The "OFF" starts blinking.
5
Turn the J-dial to select the PROTOCOL setting
(example: SANYO COAX1), and then turn the S-dial
clockwise.
The address (ADD.) is preset, it cannot be modified.
Refer to "List of camera addresses" for more
information. (P90)
Selections:
OFF: No camera control
SANYO COAX1:
Camera control by coaxial superimposition of the
SANYO (SSP) protocol.
The address is automatically displayed.
SANYO RS485:
Camera control by SANYO (SSP) protocol using
RS485.
The address is automatically displayed.
BBV COAX:
Camera control by coaxial superimposition of the
BBV protocol.
PELCO COAX:
Camera control by coaxial superimposition of the
PELCO protocol.
SANYO COAX2:
Camera control by high-speed coaxial
superimposition.
6
Press the EXIT/OSD button.
7
Press the FUNC. button.
The indicator on the FUNC. button and the control
indicators turn on. (P73)
Press the FUNC. button again to exit the function
control.
G Camera control settings
MENU
(J)
(S)
7.CAMERA CONTROL SET
3.GENERAL SET
<MAIN MENU>
<GENERAL SET>
<CAMERA CONTROL SET>
1. PROTOCOL/ADDRESS SET ->
2. ALARM REC TRIGGER SET ->
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 OFF --- 09 OFF ---
02 OFF --- 10 OFF ---
03 OFF --- 11 OFF ---
04 OFF --- 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
06 OFF ---
Third-party cameras controlled by RS485, RS422
etc. are not supported. Consult with the store where
you purchased your system regarding the types of
cameras that are supported.
In order to prevent control mistakes, set the
PROTOCOL setting to "OFF" for channels with
cameras that are not capable of coaxial
superimposition or not of the supported types.
06 SANYO COAX1 006
EXIT/OSD
FUNC.
POWERMODEAUTOMENU
Dome camera (sold separately)