English
General settings
How to set 72
Depending on the settings of the selections under
"ALARM RECORDING", the camera lens can be set to
move to a preset position or automatic panning when an
alarm is detected.
Confirm the "ALARM RECORDING" setting. (P56)
1
Display the <CAMERA CONTROL SET> screen
using "Displaying the general settings screen"
(P62).
2
Turn the J-dial to select "ALARM REC TRIGGER
SET" and then turn the S-dial clockwise.
The <ALARM REC TRIGGER SET> screen is
displayed.
3
Turn the J-dial to select the camera (CH) that will do
the trigger operation when an alarm is detected and
then turn the S-dial clockwise.
The "OFF" starts blinking.
4
Turn the J-dial to select the motion operation
(example: 05 SEQUENCE) and then turn the S-dial
clockwise.
The SEQUENCE is displayed, the cursor moves to the
"OFF" of the next camera so other cameras can be set
if necessary.
Selections:
OFF: No trigger operation.
PRESET (2~9/16): Moves to the preset number.
PAN: Starts auto panning.
TOUR: Starts tour operations.
SEQUENCE: Starts automatic sequence operation.
5
Press the EXIT/OSD button.
6
Press the FUNC. button.
The indicator on the FUNC. button and the control
indicators turn on. (P73)
Press the FUNC. button again to exit the function
control.
G-1 Alarm recording trigger settings
<ALARM REC MODE SET>
ALARM RECORDING : OFF
PICTURE QUALITY : ENHANCED
AUDIO RECORDING : OFF
ALARM INTERLEAVE : ONLY
REC RATE: 12.5FPS, DURATION: 20SEC
PRE-ALARM RECORDING : ***
REC RATE: **** FPS, DURATION: ****
=> (01731 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
MENU
(J)
(S)
7.CAMERA CONTROL SET
3.GENERAL SET
<MAIN MENU>
<GENERAL SET>
<CAMERA CONTROL SET>
1. PROTOCOL/ADDRESS SET ->
2. ALARM REC TRIGGER SET ->
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 OFF --- 09 OFF ---
02 OFF --- 10 OFF ---
03 OFF --- 11 OFF ---
04 OFF --- 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
<ALARM REC TRIGGER SET>
CH ACTION CH ACTION
01 --------- 09 ---------
02 --------- 10 ---------
03 --------- 11 ---------
04 --------- 12 ---------
05 --------- 13 ---------
06 --------- 14 ---------
07 --------- 15 ---------
08 --------- 16 ---------
Note: When several alarms are detected at the same time, it is
possible that the camera control is disabled, depending on the
camera control setting for the alarm recording.
05 SEQUENCE
EXIT/OSD
FUNC.