152 Fibre Channel Interface Manual, Rev. D
35 00 Enclosure services failure
35 01 Unsupported enclosure function
35 02 Enclosure services unavailable
35 03 Enclosure services transfer failure
35 04 Enclosure services transfer refused
37 00 Parameter rounded
3F 01 Microcode changed
3F 02 Changed operating definition
3F 05 Device identifier changed
3F 91 WWN mismatch, ETF WWN is valid
40 01 DRAM parity error
42 00 Power-on or self-test failure
43 00 Message reject error
44 00 Internal target failure
45 00 Select or reselect failure
47 00 Interface error
When the ASC and ASCQ are 47 and 00 respectively, the Sense Key Specific field of the Extended
Sense Data has the meaning defined below. Note that more than one bit may be set.
Byte 16:
Bit 7 - Invalid destination ID
Bit 6 - Invalid source ID
Bit 5 - Invalid frame type
Bit 4 - Invalid f_ctl
Bit 3 - Invalid sequence ID
Bit 2 - Invalid df_ctl
Bit 1 - Invalid sequence count
Bit 0 - Invalid 0x_id
Byte 17:
Bit 7 - Running disparity error
Bit 6 - CRC error
Bit 5 - Payload still coming after transfer count went to 0, or invalid primitive detected before EOF.
Bit 4 - EOFa — ‘abort’ detected as EOR
Bit 3 - Invalid EOF (EOFni EOFdti)
Bit 2 - Unsupported EOF
Bit 1 - Unsupported Class (Class 1 or 2 SOF primitive detected)
Bit 0 - Invalid R_CTL
48 00 Initiator detected error
49 00 Invalid message
4E 00 Overlapped commands attempted
Table 93: Error codes for bytes 12 and 13 of sense data (values are in hexadecimal) (Continued)
Byte 12
(ASC)
Byte 13
(ASCQ)
Description