Table 121 summarizes the Log Select Command field settings used when updating the cumulative/threshold value settings
and the resulting action that will occur based on these field settings.
The Log Select and Log Sense commands use the same log page format. See Section 12.10.
Table 121: Log Select Command field setting summary
PCR PC
Parameter
List Length
Resulting action
1xx0
All cumulative counter and threshold log page values will be set to “zero” on all
log pages.
0110
All cumulative counter log page values will be set to “zero” on all log pages.
0100
All threshold log page values will be set to “zero” on all log pages.
001nn
The cumulative counter for a specific parameter code will be set to the stipu-
lated value on a specified log page as found in the Log Parameter Page data.
000nn
The threshold for a specific parameter code will be set to the stipulated value
on a specified log page as found in the Log Parameter Page data.