10.1.3. Resetting alarm event recording
The Alarm reset key flashes and the buzzer tone sounds during Alarm event recording. Alarm event recording
cannot be initiated by the Remote Controller. For the method of starting the Alarm event recording, refer to the
instruction manual enclosed with the Digital Video Recorder. For the operations of the unit while in alarm
mode, refer to p. 34; Alarm Operations.
Hold down the Alarm reset key for 2 seconds or more.
The Alarm reset key extinguishes and the buzzer stops, terminating
Alarm event recording.
Notes
Press the Alarm reset key to stop a buzzer during Alarm event
recording.
The Alarm reset key lights when Alarm recording is terminated by
the Digital Video Recorder. To extinguish it, hold down the Alarm
reset key for 2 seconds or more.
10.1.4. Making normal recording
By performing the menu setting for the Digital Video Recorder, the schedule of Normal recording can be set.
Using the Remote Controller, display the Digital Video Recorder menu to set it. For details, please refer to the
instruction manual enclosed with the Digital Video Recorder.
10.2. Playback Operation
10.2.1. Playback mode settings
Press the PLAY/LIVE key.
Live mode is switched to the playback mode, commencing
playback.
The PLAY/LIVE key remains lit while in playback mode. Pressing
the PLAY/LIVE key again switches playback to live mode.
Notes
Tilting the joystick to the right while in playback
mode also permits playback to begin.
Playback begins from the position at which
playback last stopped.
10.2.2. Reverse playback
Tilt the joystick to the left while in playback mode. Reverse playback begins.
PLAY / LIVE
PLAY / LIVE
Lights
L4 L5
L6 L7
PB4 PB5
PB6 PB7
Live mode Playback mode
"L" stands for the live screen while "PB" stands
for the playback screen.
BUZZER STOP
RESET
BUZZER STOP
RESET